Search results for " Shape analysis"
showing 10 items of 35 documents
Chlorophyll fluorescence emission spectrum inside a leaf
2008
International audience; Chlorophyll a fluorescence can be used as an early stress indicator. Fluorescence is also connected to photosynthesis so it can be proposed for global monitoring of vegetation status from a satellite platform. Nevertheless, the correct interpretation of fluorescence requires accurate physical models. The spectral shape of the leaf fluorescence free of any re-absorption effect plays a key role in the models and is difficult to measure. We present a vegetation fluorescence emission spectrum free of re-absorption based on a combination of measurements and modelling. The suggested spectrum takes into account the photosystem I and II spectra and their relative contributio…
X-ray response of CdZnTe detectors grown by the vertical Bridgman technique: Energy, temperature and high flux effects
2016
Abstract Nowadays, CdZnTe (CZT) is one of the key materials for the development of room temperature X-ray and gamma ray detectors and great efforts have been made on both the device and the crystal growth technologies. In this work, we present the results of spectroscopic investigations on new boron oxide encapsulated vertical Bridgman (B-VB) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Several detectors, with the same electrode layout (gold electroless contacts) and different thicknesses (1 and 2.5 mm), were realized: the cathode is a planar electrode covering the detector surface (4.1×4.1 mm2), while the anode is a central electrode (2×2 mm2) surrounded by a guard-rin…
Digital fast pulse shape and height analysis on cadmium-zinc-telluride arrays for high-flux energy-resolved X-ray imaging.
2017
Cadmium-zinc-telluride (CZT) arrays with photon-counting and energy-resolving capabilities are widely proposed for next-generation X-ray imaging systems. This work presents the performance of a 2â...mm-thick CZT pixel detector, with pixel pitches of 500 and 250â...μm, dc coupled to a fast and low-noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to digitize and process continuously the signals from each output ASIC channel. The digital system performs on-line fast pulse shape and height analysis, with a low dead-time and reasonable energy resolution at both low and high fluxes. The spectroscopic response …
ASE narrow‐band noise pulsing in erbium‐doped fiber amplifier and its effect on self‐phase modulation
2019
In this paper, we report a study of the features of polarized and unpolarized narrow-band amplified spontaneous emission (ASE) in a low-doped erbium fiber at 976-nm pumping. We demonstrate that ASE noise can be treated as a train of Gaussian-like pulses with random magnitudes, widths, and inter-pulse intervals. ASE noise can also provide a statistical analysis of these three parameters. We also present the data that reveal ASE noise’s role in optical spectrum broadening through self-phase modulation of light propagating in a communication fiber. In particular, the data show that the ASE noise derivative defines the broadening’s spectral shape.
On the Left Ventricular Remodeling of Patients with Stenotic Aortic Valve: A Statistical Shape Analysis
2021
The left ventricle (LV) constantly changes its shape and function as a response to pathological conditions, and this process is known as remodeling. In the presence of aortic stenosis (AS), the degenerative process is not limited to the aortic valve but also involves the remodeling of LV. Statistical shape analysis (SSA) offers a powerful tool for the visualization and quantification of the geometrical and functional patterns of any anatomic changes. In this paper, a SSA method was developed to determine shape descriptors of the LV under different degrees of AS and thus to shed light on the mechanistic link between shape and function. A total of n=86 patients underwent computed tomography (…
Statistical shape analysis of ascending thoracic aortic aneurysm: Correlation between shape and biomechanical descriptors
2020
An ascending thoracic aortic aneurysm (ATAA) is a heterogeneous disease showing different patterns of aortic dilatation and valve morphologies, each with distinct clinical course. This study aimed to explore the aortic morphology and the associations between shape and function in a population of ATAA, while further assessing novel risk models of aortic surgery not based on aortic size. Shape variability of n = 106 patients with ATAA and different valve morphologies (i.e., bicuspid versus tricuspid aortic valve) was estimated by statistical shape analysis (SSA) to compute a mean aortic shape and its deformation. Once the computational atlas was built, principal component analysis (PCA) allow…
Insight into the noble crayfish morphological diversity: a geometric morphometric approach.
2022
The noble crayfish (Astacus astacus), a keystone species of high ecological, economic, and cultural importance in Europe, is threatened due to a long-term population decline caused by anthropogenic pressure on its habitats, the presence of non-indigenous invasive crayfish species and climate change. Since the effective protection of the remaining populations requires conservation measures based on the comprehensive knowledge of the species, including good understanding of its genetic and morphological variability, our aim was to study morphological features of the noble crayfish in Croatia using geometric morphometrics for the first time. We applied two-dimensional geometric morphometrics t…
Apparent absorption of solar spectral irradiance in heterogeneous ice clouds
2010
[1] Coordinated flight legs of two aircraft above and below extended ice clouds played an important role in the Tropical Composition, Cloud and Climate Coupling Experiment (Costa Rica, 2007). The Solar Spectral Flux Radiometer measured up- and downward irradiance on the high-altitude (ER-2) and the low-altitude (DC-8) aircraft, which allowed deriving apparent absorption on a point-by-point basis along the flight track. Apparent absorption is the vertical divergence of irradiance, calculated from the difference of net flux at the top and bottom of a cloud. While this is the only practical method of deriving absorption from aircraft radiation measurements, it differs from true absorption when…
Structural and functional organization of fish assemblages in a Mediterranean shallow CO2 vent.
2017
Gli effetti dell’acidificazione degli oceani a livello globale hanno richiamato l’attenzione degli scienziati su dei sistemi marini naturali quali i vent superficiali di CO₂. Si tratta di mesocosmi naturali, in quanto su piccole scale spaziali (anche di pochi metri) si osservano marcati gradienti di pH, dove poter testare ipotesi ecologiche dell’acidificazione delle acque marine. Obiettivo della tesi è studiare le risposte della popolazione ittica alla riduzione del pH in vent superficiali mediterranei utilizzando numerosi descrittori, quali la struttura di comunità, l’organizzazione trofica, le caratteristiche e la composizione chimica delle strutture carbonatiche. Inoltre poiché i vent so…
The scattering and re-absorption of red and near-infrared chlorophyll fluorescence in the models Fluspect and SCOPE
2019
Scattering and re-absorption have been recognized as relevant aspects for the interpretation of solar induced chlorophyll fluorescence (SIF) in vegetation remote sensing. In an earlier study [Yang and Van der Tol, RSE 215, 97–108, 2018] we addressed the problem of scattering and re-absorption of near-infrared fluorescence in the vegetation canopy. In this study we analyse within-leaf re-absorption of both red and near-infrared fluorescence using the radiative transfer model Fluspect. The leaf scattering determines the ratio of backward to total leaf fluorescence emission Fb/(Fb + Ff). Fluspect reproduces this ratio with an RMSE of less than 0.1, and explains the observed dependence of the s…